A filler that dispenses reliably on one oil may still be awkward to change over. The useful question is not whether the machine has a purge button. It is what remains in the fluid path, how the approved cleaning method deals with it, and what evidence supports restarting. The examples refer to a semi-automatic cartridge filler.
This checklist is for teams comparing or qualifying machines for 510 cartridges and AIO devices. It helps you ask for evidence and measure a trial. It is not a cleaning recipe and sets no residue limits, purge volumes or time benchmarks. Those belong to the current equipment instructions and your facility’s approved procedure. If the equipment is new to your team, start with how a semi-automatic filler works.
Start with the exact change you expect to make
Describe the outgoing and incoming formulations, planned batch sizes, hardware models and machine configuration. Switching hardware fixtures is not the same problem as changing the material in the fluid path, so plan and time them separately. A cleaning demonstration using a convenient test fluid also cannot establish that the same method suits your intended oils.
Tell the vendor what the changeover must achieve. That might include removing the previous formulation, clearing the cleaning medium, preparing a different needle or fixture, and verifying the next fill. “Ready for another flavor” is too vague. Name the materials involved and who decides whether the next run may start.
If you have not shortlisted equipment, use our cartridge filling machine selection checklist first. Here, the narrower question is whether a particular changeover can be performed and supported with evidence.
Ask for a map of what actually touches the oil
Request a current fluid-path drawing or component list for the quoted setup. Wetted parts are every surface the formulation touches along the fluid path. Ask the vendor to identify the reservoir outlet, pump, valves, seals, tubing, fittings and dispensing needle wherever they are present in that configuration.
For each part, establish how it is accessed, which materials it contains, which cleaning methods the manufacturer permits, and whether inspection or replacement is required. A stainless-steel enclosure does not answer those questions. Neither does a photograph of a clean reservoir if the downstream path is outside the picture.
A removable tank does not necessarily make the entire path removable. Ask the vendor to show what happens to the material between the tank outlet and needle, including any locations the operator cannot inspect directly. Note unresolved points rather than guessing from product photos.
Separate draining, purging and cleaning
These words can describe different tasks. For your trial record, define draining as removing accessible bulk material, purging as displacing material through the path, and cleaning as the approved treatment of the specified surfaces. The manufacturer may use different terminology; reconcile it before you compare machines.
Vendor documentation shows why a purge control is only part of the answer. As of October 2026, CoolJarz’s HotShot Pro SE page describes clean/purge controls, while its HotShot-family maintenance directory lists component-specific work such as valve removal and filter replacement. The directory covers the wider family, so each listed task is not necessarily a Pro SE instruction. Neither page gives a procedure for another machine or shows a validated result for your formulations.
Ask for the written sequence, permitted materials and operator training for the exact machine revision. Do not import solvent concentrations, temperatures, soak times or purge quantities from another vendor’s video. If the instructions leave compatibility unclear, resolve it with the equipment supplier and the people responsible for your process before running the trial.
Decide what “clean enough to restart” means before testing
Visual inspection can show accessible residue, but an acceptable appearance alone does not tell you the carryover result. Carryover means material from the previous run entering the next one. Decide what must be checked, where and when samples are taken, what the method can detect, and who approves the result.
The method and criteria depend on the formulation, equipment, intended product and applicable requirements. Have the responsible technical or quality personnel define them. Record the inspection or test method alongside its result; “passed cleaning” without a method is difficult to compare or investigate later.
Keep outgoing oil, cleaning output and startup fills under separate identities until the required restart checks are complete. Administrative batch separation belongs in our line-clearance and batch-changeover guide; it complements fluid-path verification rather than replacing it.
Measure the interval that matters to your schedule
For a scoped trial, time the interval from the last accepted unit of the outgoing run to the first accepted unit of the incoming run. Define both endpoints and the checks needed for acceptance before starting the clock. Keep this trial measure distinct from advertised dispense speed or sustained production throughput.
Break the interval into:
- outgoing-material handling;
- cleaning or parts replacement;
- reassembly and setup;
- startup filling;
- verification or release waiting.
Record active operator time separately from elapsed time. This makes a long changeover explainable: a short dispensing step may sit inside a much longer sequence. Changeover timing is one part of the broader evaluation covered in our cartridge filler acceptance-trial guide.
Identify the operator, machine revision, formulations, hardware and trial conditions. A single demonstration is not a reliable universal time estimate. Repeat trials where your evaluation plan calls for them and keep interruptions visible rather than excluding inconvenient results.
Track purge output and material use
Use separate records for material removed from the machine, purge or cleaning output, rejected startup fills and accepted incoming units. Whether any removed material can be recovered or reused is a separate authorized decision; its appearance does not establish suitability. Handle and dispose of each category under the applicable facility procedures.
If weighing is part of the evaluation, identify the containers, tare method and suitable measuring equipment. Keep masses distinct from volume settings. Do not imply that one milliliter of every formulation weighs one gram. Record unexplained differences rather than claiming a complete mass balance from incomplete observations.
Use the trial data in a cost comparison with clearly stated assumptions: operator time, consumables, replacement parts and material disposition can all affect the result. Compare machines on the same assumptions, or the numbers will not be comparable.
Send a focused evidence request
Before approving a multi-formulation setup, ask the vendor for:
- the exact fluid-path configuration and wetted-material documentation;
- current cleaning, disassembly, reassembly and safety instructions;
- permitted cleaning media and any compatibility restrictions;
- the demonstration scope, including which formulation and hardware were actually used;
- changeover timing and material records with defined endpoints;
- startup checks, unresolved limitations and who signs off on restart.

If the GT10 cartridge filling machine is on your shortlist, use the evidence list above when contacting ILEVA for its current configuration and maintenance documentation. Check the response against the changeover you actually plan to run. This article is not a GT10 cleaning procedure and does not offer verified GT10 purge-loss or changeover-time figures.
A useful changeover comparison ends with more than a tidy machine photo. You should know which surfaces were addressed, what procedure was used, how the restart decision was made, and what time and material the transition consumed. If any of those answers is missing, note the gap before approving the next run.